LIST OF REFERENCES FOR CHAPTER 1
1.

ICRP Publication 60, 1990 Recommendations of the International Commission on Radiological Protection, Annals of the ICRP Vol. 21 Nos. 1-3 (Pergamon Press, Oxford) (1991)

2.

ICRP Publication 34, Protection of the Patient in Diagnostic Radiology, Annals of the ICRP Vol. 9 Nos. 2-3 (Pergamon Press, Oxford) (1982)

3.

ICRP Publication 73, Radiological Protection and Safety in Medicine, Annals of the ICRP Vol. 26 No. 2 (Pergamon Press, Oxford) (1996)

4.

Council Directive 97/43/EURATOM of 30 June 1997 on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure. O.J. No. L 180, p. 22, 9.7.1997. (Repealing Directive 84/466/EURATOM, O.J. L 265, p.1, 5.10.1984)

5.

European Guidelines on Quality Criteria for Diagnostic Radiographic Images, Report EUR 16260 (1996)

6.

European Guidelines on Quality Criteria for Diagnostic Radiographic Images in Paediatrics, Report EUR 16261 (1996)

7.

Hidajat N, Schröder RJ, Vogl T, Schedel H and Helix R. Effektivität der Bleiabdeckung zur Dosisreduktion beim Patienten in der Computertomographie. Fortschritte Röntgenstrahlen, 165, 462 - 465 (1996)

8.

Beaconsfield T, Nicholson R, Tornton A and Al-Kutoubi A. Would thyroid and breast shielding be beneficial in CT of the head? European Radiology, 8, 664 - 667 (1998)

9.

Shrimpton PC, Jones DG, Hillier MC, Wall BF, Le Heron JC and Faulkner K. Survey of CT practice in the UK. Part 2: Dosimetric aspects. Chilton, NRPB-R249 (London, TSO) (1991)

10.

Brink JA, McFarland EG and Heiken JP. Helical/spiral computed body tomography. Clinical Radiology, 52 (7), 489-503 (1997)

11.

Costello P, Dupuy DE, Ecker CP and Tello R. Spiral CT of the thorax with reduced volume of contrast material: a comparative study. Radiology, 183 (3), 663-666 (1992)

12.

Jurik AG and Albrechtsen J. Spiral-CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall disorders. Acta Radiologica, 35, 468-472 (1994)

13.

Kalender WA. Technical foundations of spiral CT. Seminars in Ultrasound, CT and MRI, 15 (2), 81-89 (1994)

14.

Verdun FR, Meuli RA, Bochud FO, Imsand C, Raimondi S, Schnyder P and Vally J-F. Image quality and dose in spiral computed tomography. European Radiology, 6, 485-488 (1996)

15.

Reynolds MD, Heuscher DJ and Vembar M. Evaluation of spiral CT on a fourth-generation system. European Radiology, 5, 102-109 (1995)

16.

International Electrotechnical Commission: Evaluation and routine testing in medical imaging departments. Part 2 - 6: Constancy tests - x-ray equipment for computed tomography, 1994: IEC 1223-2-6 (Geneva, IEC)

17.

Jurik AG, Petersen J, Bongartz, Golding SJ, Leonardi M, van Meerten PvE, Geleijns J, Jessen KA, Panzer W, Shrimpton P, Tosi G. Clinical use of image quality criteria in computed tomography related to radiation dose. A pilot study. European Radiology (to be submitted)